Automatic Oil Chromatography Analyzer

Product overviewHTYSP-H adopts the isolated and analysis techniques of multicomponent mixture. It mainly makes use of the differences in the samples of the component boiling point, polarity and the adsorption coefficient in the chromatographic column, to make the components  isolated in the chromatographic column, and

Featured Products

Product overview
HTYSP-H adopts the isolated and analysis techniques of multicomponent mixture. It mainly makes use of the differences in the samples of the component boiling point, polarity and the adsorption coefficient in the chromatographic column, to make the components  isolated in the chromatographic column, and qualitative and quantitative analyze the isolated components.
HTYSP-H oil chromatographic analyzer in accordance with the power system, "insulating oil dissolved gas component content mensuration (chromatography)" requirement, uses micro-computer control, full keyboard, large screen LCD display, with high precision, stable and reliable performance, high sensitivity, good repeatability etc.
The instrument uses two columns in parallel shunt system. Equipped with TCD and double FID and methane reformer, one sample injection can achieve full analysis of seven components of the oil dissolved gas (H2, CH4, C2H2, C2H4, C2H6, CO, CO2), if necessary can do full analysis of nine components (H2, O2, N2, CH4, C2H2, C2H4, C2H6, CO, CO2)


Products features
1.Using advanced technology 10 / 100M adaptive Ethernet communication interface, and built-in IP protocol stack, can easily through the enterprise intranet and Internet for remote data transmission; Convenient for laboratory construction, simplify  the laboratory configuration, convenient for management of data analysis
2. The Internal of instrument designed three separated connection process, can connect to the local processing site (laboratory), unit director (such as quality inspection chief, production factory director, etc.), and higher authorities (e.g., environmental protection bureau, bureau of technical supervision, etc.). Can easy to real-time monitor the operation of the instrument and the analysis of data results
3. Optional NetChromTM workstation can simultaneously support multiple chromatographic analyzer work, data processing and control, simplifies document management, and reduces the user's investment and operating costs
4. System with Chinese and English operating system, the user can switch according to their needs
5. Temperature control area can be freely named by the user, convenient for use.
6.The instrument uses the multi-processor parallel work mode, stable and reliable; can meet the complex sample analysis, can optional high-performance detectors, such as FID, TCD, ECD, FPD and NPD, can be installed four detectors at the same time.
7. Adopts the modular structure, design and clear, easy to replace and upgrade, to protect the effectiveness of investments
8.The new microcomputer temperature control system, high precision temperature control, superior reliability and anti-jamming performance; with six fully independent temperature control system can be realized 16 stages temperature programming, so the device is qualified for a wider range of sample analysis; with oven automatic back opening door system, the low temperature control accuracy is improved, up / cool down faster
9. Can optional advanced electronic flow controller (EFC), electronic pressure controller (EPC), to realize the digital control, can greatly improve the reproducibility of qualitative and quantitative results
10. With timing self-starting program, it can easily complete on-line analysis of gas samples (equipped with on-line automatic sample parts required)
11. Full computer control keyboard operating system, simple operation, and design a detector with automatic identification technology. With fault diagnosis, and power-off data protection function, automatic memory setting parameters
12. Built-in low noise, high-resolution 24 AD circuit, and with the function of baseline storage and baseline deduction
13. Chromatographic signals acquisition and data processing, suitable for WinXP, Win2000, Windows7 operating systems. In line with the A / A (USA Analysis Society) standard CDF file is read into the sampling data, it can be integrated with Agilent, Waters and other chromatography workstation
14. The chromatographic system with completely independent intellectual property rights, with the MODBUS/TCP standard interface, easy for docking DCS
15. The device can be docked with many of  automatic samplers; such as Shimadzu AOC-20i, Italy HTA company's HT series high-performance liquid, gas auto-sampler, etc


Technique parameters
Main parameters
Display 192×64 LCD
Temperature control area6 loops
Temperature control range Room temperature: +5ºC~400ºC, increment: 1ºC, accuracy: ±0.1ºC
Programmed temperature order16
Program rise rate0.1~40ºC/min
Gas path controlMechanical valve control mode, electronic pressure flow control mode
external4 loops
Sample injector typeFilling column, capillary tube, six way valve gas inlet, automatic headspace sampling, etc.
Number of detectors5: FID, TCD, ECD, FPD, NPD (optional)
Start samplingManual, auto
Communication IEEE802.3
Detector parameters
FID 
Range ≤3×10-12g/s (n-hexadecane/ isooctane)
Baseline noise≤5×10-14A
Baseline drift≤1×10-13A/30min
Linear range≥107
TCD 
SensitivityS≥10000mV.ml/mg(benzene, toluene) (Amplification 1, 2, 4, 8 times optional)
Number of detectors5: FID, TCD, ECD, FPD, NPD (optional)
Baseline noise≤20μV
Baseline drift≤30μV/30min
Linear range≥105
ECD 
Range≤1×10-14g/ml(lindane / isooctane)
Baseline noise≤0.03mV
Baseline drift≤0.2mV/30min
Linear range≥104
Radioactive Source63Ni
Detection limit(S)≤2×10-11g/s ,(P)≤1×10-12g/s  (parathion-methyl / Absolute alcohol)
Baseline noise≤3×10-13A
Baseline drift≤2×10-12A/30min
Linear rangesulfur≥103, phosphorus≥104
Automatic Oil Chromatographic Analyzer
Automatic Oil Chromatographic Analyzer
Automatic Oil Chromatographic Analyzer
Automatic Oil Chromatographic Analyzer
Automatic Oil Chromatographic Analyzer
Automatic Oil Chromatographic Analyzer
Automatic Oil Chromatographic Analyzer

Common problem
1. Is your company a sales company or a manufacturer?
Wuhan Huatian Electric Power Automation CO., LTD.is an industrial and trade enterprise, with its own  factory, self-produced and self-sold. We were founded in 2004 and have fifteen years of production experience. Our company has reliable production lines, test rooms and R&D centers.

2. Whether the goods are in stock, whether they can be customized, and how long the delivery time is.
After the goods have been ordered, we can be made to order according to the special requirements of customers by using the latest technology. The delivery time is usually within 10 working days if there are no accidents.

3. Is the quality guaranteed?
In order to ensure quality, we use imported components in large quantities. After three times of quality inspection, the goods can be sent out, and the export is uniformly packed in non-fumigation wooden boxes.

4. What are the after-sales terms?
We offer free consulting service, one year warranty, and adopt various methods such as email communication, video calls, technology door-to-door, aiming to solve any after-sales problems in a timely manner.

5. What are the cooperative countries or regions?
Products have been successfully exported to the United States, Brazil, Australia, Russia, the Netherlands, Indonesia, Bangladesh, Iran, India, Saudi Arabia, Mongolia, Japan and other countries and regions. In the United States, India, Vietnam and other regions have cooperative distributors, can provide thoughtful services.



Contact us

Wuhan Huatian Electric Power Automation CO., LTD


Address: T4, No. 1, High-tech 2 Road,East Lake High-tech Development Zone,Wuhan
Zip code: 430074
Tel:(+86)-27-8745 7960 / (+86)027-87993136 / 13808601259
Fax: (+86)-27-8799 3136
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours